 The original version of this article unfortunately contained a mistake in Table 3. The initial levels of Tg Ab was incorrectly transcribed. The corrected Table 3 is given below.
 
 Endocrine Table 3 Baseline characteristics and comparison of the responses to therapy in patients with detectable TgAb with and without radioiodine remnant ablation Radioiodine remnant ablation (RA) Without RA (n = 23) Sex (n, %) Female 18 (78.3) Male 5 (21.7) Age (years) Median (range) 42 (27–69) Histology (n, %) Papillary 22 (95.7) Follicular 1 (4.3) Lymphocytic thyroiditis (n, %) 17 (73.9) Initial TgAb median IU/ml (range) 194 (0–2000) TgAb trend at 12 months (n, %) Undetectable 5 (21.7) Decreased 14 (60.9) Stable 1 (4.3) Increased 3 (13) Unknown 0 Initial response to treatment (n, %) Excellent response 8 (34.8) Indeterminate response 15 (65.2) Biochemical incomplete 0 Structural incomplete 0 Clinical status at 36 months of follow up NED (n, %) 8 (34.8) Indeterminate (n, %) 15 (65.2) Biochemical incomplete (n, %) 0 Structural incomplete (n, %) 0 Time to undetectable TgAb (months) Median (range) 11.25 (6–21) Time of follow-up (months) Median (range) 27 (16–42)
 
 With RA (n = 30)
 
 p
 
 27 (90) 3 (10)
 
 0.237a
 
 44 (29–76)
 
 0.2697b
 
 30 (100) 0 14 (46.7) 98 (0–1180)
 
 0.249a 0.741a 0.1435b
 
 1 15 6 2 6
 
 (3.3) (50) (20) (6.7) (20)
 
 0.006a
 
 7 21 1 1
 
 (23.4) (70) (3.3) (3.3)
 
 0.610a
 
 9 (30) 19 (63.3) 0 2 (6.7)
 
 0.442a
 
 16 (11–36)
 
 0.0232b
 
 82 (27–210)
 
 RA radioiodine remnant ablation, TgAb anti-thyroglobulin antibodies, NED no evidence of disease a
 
 p values were determined by the χ2 test p values were determined by the Mann–Whitney U test
 
 b		
Data Loading...
 
	 
	 
	 
	 
	 
	 
	 
	 
	 
	 
	