Dynamic Isolation Technologies in Negative Pressure Isolation Wards
This book presents novel design principles and technologies for dynamic isolation based on experimental studies. These approaches have now become the local standard in Beijing and are currently being promoted for use nationwide. Further, the book provides
- PDF / 7,038,551 Bytes
- 220 Pages / 453.543 x 683.15 pts Page_size
- 118 Downloads / 218 Views
namic Isolation Technologies in Negative Pressure Isolation Wards
Dynamic Isolation Technologies in Negative Pressure Isolation Wards
Zhonglin Xu Bin Zhou •
Dynamic Isolation Technologies in Negative Pressure Isolation Wards
123
Zhonglin Xu China Academy of Building Research Beijing China
ISBN 978-981-10-2922-6 DOI 10.1007/978-981-10-2923-3
Bin Zhou Nanjing Tech University Nanjing China
ISBN 978-981-10-2923-3
(eBook)
Library of Congress Control Number: 2016957494 © Springer Nature Singapore Pte Ltd. 2017 This work is subject to copyright. All rights are reserved by the Publisher, whether the whole or part of the material is concerned, specifically the rights of translation, reprinting, reuse of illustrations, recitation, broadcasting, reproduction on microfilms or in any other physical way, and transmission or information storage and retrieval, electronic adaptation, computer software, or by similar or dissimilar methodology now known or hereafter developed. The use of general descriptive names, registered names, trademarks, service marks, etc. in this publication does not imply, even in the absence of a specific statement, that such names are exempt from the relevant protective laws and regulations and therefore free for general use. The publisher, the authors and the editors are safe to assume that the advice and information in this book are believed to be true and accurate at the date of publication. Neither the publisher nor the authors or the editors give a warranty, express or implied, with respect to the material contained herein or for any errors or omissions that may have been made. Printed on acid-free paper This Springer imprint is published by Springer Nature The registered company is Springer Nature Singapore Pte Ltd. The registered company address is: 152 Beach Road, #22-06/08 Gateway East, Singapore 189721, Singapore
Preface
After the epidemic of the infectious disease SARS occurred in 2003, a simulated negative pressure ward was set up in Institute of HVAC at China Academy of Building Research. The series of experiment were carried out by author and one group. Ten serial research reports and one monograph were published. The proposal of one concept and its corresponding technical measures was completed. The first construction standard in China for negative pressure ward was compiled in Beijing, which has been referred and adopted by other local standards. Nowadays with frequent occurrence of airborne infectious diseases, the new manuscript is prepared based on the above-mentioned research reports and monograph. It is hoped that the effective measures proved by research could be introduced to more people. Acknowledgement is given to Assoc. Prof. Dr. Zhou Bin from Nanjing Tech University, who is responsible for the translation of this monograph. Last but not least, supports from the National Natural Science Foundation of China (No. 51508267), the Natural Science Foundation of Jiangsu Province (No. BK20130946), Research Project for Reform of Higher Education and Teaching from Department of Ed
Data Loading...