Improved parameter-estimation with combined PET-MRI kinetic modelling
- PDF / 170,911 Bytes
- 1 Pages / 595.276 x 793.701 pts Page_size
- 21 Downloads / 245 Views
MEETING ABSTRACT
Open Access
Improved parameter-estimation with combined PET-MRI kinetic modelling Kjell Erlandsson1*, Maria Liljeroth1, David Atkinson2, Simon Arridge3, Sebastien Ourselin4, Brian Hutton1,5 From PSMR 2015: 4th Conference on PET/MR and SPECT/MR La Biodola, Isola d’Elba, Italy. 17-21 May 2015 1 Institute of Nuclear Medicine, University College London, London, UK
Kinetic analysis can be applied both to dynamic PET and dynamic contrast enhanced (DCE) MRI data. We have investigated the potential of combined PET-MRI kinetic modelling using simulated FDG data. The volume of distribution, Ve, for the extravascular extra-cellular space (EES) can be estimated by DCE-MRI, and used to reduce the number of parameters in the PET model. We use a 3 tissue-compartment model with 5 rate constants (3TC/5k), in order to distinguish between EES and the intracellular space (EIS). In the standard models, k3 represents transfer from the unmetabolised to the metabolised (M) extra- vascular compartment. In our new model, k3’ represents transfer from EES to the EIS M-compartment. We also define the more biologically relevant constant, k3"=Vek3’, to be used together with the true EES tracerconcentration. Time-activity curves were generated using the 3TC/5k-model with 3 different Ve- values, but constant k3”. Noise was added and the data were fitted with the 2TC/3k model and with the constrained and-un-constrained 3TC/5k model. 100 noise- realisations were generated at 4 different noise-levels. For the standard 2TC/3kmodel, the estimated k3-values were in the range [0.053, 0.094] with SD in the range [0.002,0.043] /min. For the un-constrained 3TC/5k model, the k3"-values were in the range [0.041,0.187] and SD in [0.053,0.208] /min. With fixed Ve the range of k3” is reduced to [0.083,0.091] with SD in [0.002,0.017] /min. The true k3” value was 0.091/min. By incorporating information from DCE-MRI into the PET kinetic model, we obtained a good estimate of the parameter k3”, independent of Ve. Authors’ details 1 Institute of Nuclear Medicine, University College London, London, UK. 2Centre for Medical Imaging, University College London, London, UK. 3Department of Computer Science, University College London, London, UK. 4Centre for Medical Imaging Computing, University College London, London, UK. 5The Centre for Medical Radiation Physics at the University of Wollongong, Northfields Ave, Wollongong, Australia. Published: 18 May 2015
doi:10.1186/2197-7364-2-S1-A25 Cite this article as: Erlandsson et al.: Improved parameter-estimation with combined PET-MRI kinetic modelling. EJNMMI Physics 2015 2(Suppl 1):A25.
© 2015 Erlandsson et al; licensee Springer. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Data Loading...