K-wire fixation vs 23-gauge percutaneous hand- crossed hypodermic needle for the treatment of distal phalangeal fractures Letizia Senesi1,2, Andrea Marchesini1, Pier Paolo Pangrazi1, Marialuisa De Francesco3, Antonio Gigante2, Michele Riccio1 and Francesco De Francesco1*

Abstract Background: Distal Phalanx (DP) fractures are the most common hand injuries. Bone fixation associated with soft tissue reconstruction, is often required to ensure more effective outcomes. The aim of the present study is to compare functional outcomes of DP fractures surgically treated with crossed manual drilled 23 Gauge needles vs crossed Kirschner-wires (k-wire). Methods: Clinical data included analysis of patient demographics, range of motion (ROM), and complications. Radiographic assessment considered fracture type, location, fracture displacement, and radiographic union. Functional outcomes analysis was performed.The statistical significance was assessed at the level of probability lower than 5%. Results: A total of 60 patients from 2012 to 2015 were retrospectively enrolled and among them 12 patients suffering from diabetes or current smokers. A total of 60 DP fractures were treated, 32 with needles (group A) and 28 with k-wire fixation (group B). Time to union, showed in different time points, was significantly lower in group A (≤ 40 days, p = 0.023*) compared to group B. ROM of the distal interphalangeal joint at six months follow-up was 60° in group A and 40° in group B. A significant improvement was observed (p = 0.001*) in the 23 G needle treated group. Functional outcome analysis showed that VAS was significantly lower in group A compared to group B (p = 0.023*). Conclusion: Our study showed that the 23 G needle yielded satisfactory results in terms of time to union and range of motion compared to k-wire fixation especially for tuft and shaft DP fractures. Therefore, should be a valid alternative to k-wire fixation in selected patients. Keywords: Distal interphalangeal fracture, Needle fixation, K-wire fixation, Range of motion, Time to union

* Correspondence: [email protected] 1 Department of Reconstructive Surgery and Hand surgery, Azienda Ospedaliera Universitaria “Ospedali Riuniti”, Via Conca 71, 60126 Ancona, Italy Full list of author information is available at the end of the article © The Author(s). 2020 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statut