Physical and Statistical Models for Steam Generator Clogging Diagnosis
Clogging of steam generators in nuclear power plants is a highly sensitive issue in terms of performance and safety and this book proposes a completely novel methodology for diagnosing this phenomenon. It demonstrates real-life industrial applications of
- PDF / 5,411,664 Bytes
- 102 Pages / 439.37 x 666.142 pts Page_size
- 77 Downloads / 196 Views
Sylvain Girard
Physical and Statistical Models for Steam Generator Clogging Diagnosis 123
SpringerBriefs in Applied Sciences and Technology
More information about this series at http://www.springer.com/series/8884
Sylvain Girard
Physical and Statistical Models for Steam Generator Clogging Diagnosis
123
Sylvain Girard Institute of Radiological Protection and Nuclear Safety (IRSN) Fontenay-aux-Roses France
ISSN 2191-530X ISBN 978-3-319-09320-8 DOI 10.1007/978-3-319-09321-5
ISSN 2191-5318 (electronic) ISBN 978-3-319-09321-5 (eBook)
Library of Congress Control Number: 2014944716 Springer Cham Heidelberg New York Dordrecht London The Author(s) 2014 This work is subject to copyright. All rights are reserved by the Publisher, whether the whole or part of the material is concerned, specifically the rights of translation, reprinting, reuse of illustrations, recitation, broadcasting, reproduction on microfilms or in any other physical way, and transmission or information storage and retrieval, electronic adaptation, computer software, or by similar or dissimilar methodology now known or hereafter developed. Exempted from this legal reservation are brief excerpts in connection with reviews or scholarly analysis or material supplied specifically for the purpose of being entered and executed on a computer system, for exclusive use by the purchaser of the work. Duplication of this publication or parts thereof is permitted only under the provisions of the Copyright Law of the Publisher’s location, in its current version, and permission for use must always be obtained from Springer. Permissions for use may be obtained through RightsLink at the Copyright Clearance Center. Violations are liable to prosecution under the respective Copyright Law. The use of general descriptive names, registered names, trademarks, service marks, etc. in this publication does not imply, even in the absence of a specific statement, that such names are exempt from the relevant protective laws and regulations and therefore free for general use. While the advice and information in this book are believed to be true and accurate at the date of publication, neither the authors nor the editors nor the publisher can accept any legal responsibility for any errors or omissions that may be made. The publisher makes no warranty, express or implied, with respect to the material contained herein. Printed on acid-free paper Springer is part of Springer Science+Business Media (www.springer.com)
Preface
This book describes a diagnosis method for steam generator clogging diagnosis and the process of its elaboration. It is mainly intended for nuclear maintenance engineers and industry researchers. As a strong emphasis was put on methodology, it can also be useful for physical modellers in general interested in the use of statistics for ‘‘model exploration’’. Besides, members of the computer experiment community will find here a detailed account of the application of modern techniques on real-world model and data, formulated in a way to be as much reprodu