Prediction of CT Substitutes from MR Images Based on Local Sparse Correspondence Combination

Prediction of CT substitutes from MR images are clinically desired for dose planning in MR-based radiation therapy and attenuation correction in PET/MR. Considering that there is no global relation between intensities in MR and CT images, we propose local

  • PDF / 2,376,651 Bytes
  • 8 Pages / 439.363 x 666.131 pts Page_size
  • 92 Downloads / 171 Views

DOWNLOAD

REPORT


Abstract. Prediction of CT substitutes from MR images are clinically desired for dose planning in MR-based radiation therapy and attenuation correction in PET/MR. Considering that there is no global relation between intensities in MR and CT images, we propose local sparse correspondence combination (LSCC) for the prediction of CT substitutes from MR images. In LSCC, we assume that MR and CT patches are located on two nonlinear manifolds and the mapping from the MR manifold to the CT manifold approximates a diffeomorphism under a local constraint. Several techniques are used to constrain locality: 1) for each patch in the testing MR image, a local search window is used to extract patches from the training MR/CT pairs to construct MR and CT dictionaries; 2) k-Nearest Neighbors is used to constrain locality in the MR dictionary; 3) outlier detection is performed to constrain locality in the CT dictionary; 4) Local Anchor Embedding is used to solve the MR dictionary coefficients when representing the MR testing sample. Under these local constraints, the coefficient weights are linearly transferred from MR to CT, and used to combine the samples in the CT dictionary to generate CT predictions. The proposed method has been evaluated for brain images on a dataset of 13 subjects. Each subject has T1- and T2-weighted MR images, as well as a CT image with a total of 39 images. Results show the effectiveness of the proposed method which provides CT predictions with a mean absolute error of 113.8 HU compared with real CTs. Keywords: CT Prediction, Outlier Detection, Local Anchor Embedding.

1

Introduction

Prediction of CT substitutes from MR images is important for dose planning in MRbased radiation therapy [1] and attenuation correction in PET/MR [2, 3]. MR images have shown many advantages compared to CT for radiation treatment planning, such as reducing X ray irradiation and improving target delineation. However, MR images do not contain electron density information which is needed for dose calculations in radiotherapy. In addition, PET/MR has shown its advantages and been used in many applications. To accurately quantify the radionuclide uptake, PET images need to be corrected for photon attenuation. However, the signals in MR images are not directly *

Corresponding author.

© Springer International Publishing Switzerland 2015 N. Navab et al. (Eds.): MICCAI 2015, Part I, LNCS 9349, pp. 93–100, 2015. DOI: 10.1007/978-3-319-24553-9_12

94

Y. Wu et al.

related to the attenuation coefficients of radiation. Given that CT intensity is directly related to electron density, CT images are usually used for MR-based dose planning and attenuation correction for PET imaging. Therefore, accurate prediction of CT images from MR images is highly desired for clinical applications. Recently, various methods for prediction of CT substitutes from MR data have been proposed. These methods mainly belong to two categories: segmentation-based and atlas-based methods. Segmentation-based methods [4, 5] usually classify voxels in MR images into