Risk factors for implant failure in reverse oblique and transverse intertrochanteric fractures treated with proximal fem

  • PDF / 854,710 Bytes
  • 8 Pages / 595.276 x 790.866 pts Page_size
  • 50 Downloads / 209 Views

DOWNLOAD

REPORT


(2019) 14:350

RESEARCH ARTICLE

Open Access

Risk factors for implant failure in reverse oblique and transverse intertrochanteric fractures treated with proximal femoral nail antirotation (PFNA) Youliang Hao, Zhishan Zhang, Fang Zhou*, Hongquan Ji, Yun Tian, Yan Guo, Yang Lv, Zhongwei Yang and Guojin Hou

Abstract Background: The incidence of intertrochanteric hip fracture is expected to increase as the global population ages. It is one of the most important causes of mortality and morbidities in the geriatric population. The incidence of reverse oblique and transverse intertrochanteric (AO/OTA 31-A3) fractures is relatively low; however, the incidence of implant failure in AO/OTA 31-A3 fractures is relatively high compared with that in AO/OTA 31-A1 and A2 fractures. To date, the risk factors for implant failure in AO/OTA 31-A3 fractures treated with proximal femoral nail antirotation (PFNA) have remained ambiguous. The purpose of this study was to identify the predictive factors of implant failure in AO/OTA 31-A3 fractures treated with PFNA. Methods: The data of all patients who underwent surgery for trochanteric fractures at our institution between January 2006 and February 2018 were retrospectively reviewed. All AO/OTA 31-A3 fractures treated with PFNA were included. Logistic regression analysis of potential predictors of implant failure was performed. Potential predictors included age, sex, body mass index, fracture type, reduction method, status of posteromedial support and lateral femoral wall, reduction quality, tip-apex distance and position of the helical blade in the femoral head. Results: One hundred four (9.3%) patients with AO/OTA 31-A3 fractures were identified. Forty-five patients with AO/OTA 31-A3 fractures treated with PFNA were suitable for our study. Overall, implant failure occurred in six (13.3%) of forty-five patients. Multivariate analysis identified poor reduction quality (OR, 28.70; 95% CI, 1.91–431.88; p = 0.015) and loss of posteromedial support (OR, 18.98; 95% CI, 1.40–257.08; p = 0.027) as factors associated with implant failure. Conclusions: Poor reduction quality and loss of posteromedial support are predictors of implant failure in reverse oblique and transverse intertrochanteric fractures treated with PFNA. Keywords: Risk factors, Implant failure, Reverse oblique intertrochanteric fractures, AO/OTA 31-A3 fractures, PFNA

* Correspondence: [email protected] Department of Orthopedics, Peking University Third Hospital, No. 49, North Garden Rd., Haidian District, Beijing 100191, China © The Author(s). 2019 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/pu