A one-year cohort study of complications, continuation, and failure rates of postpartum TCu380A in Tanzania
- PDF / 1,116,579 Bytes
- 10 Pages / 595.276 x 790.866 pts Page_size
- 12 Downloads / 156 Views
RESEARCH
Open Access
A one-year cohort study of complications, continuation, and failure rates of postpartum TCu380A in Tanzania France John Rwegoshora1, Projestine Selestine Muganyizi2*, Grasiana Festus Kimario3, Ponsian Patrick Paul3 and Anita Makins4
Abstract Background: Less than 1% of married women in Tanzania use an Intrauterine Contraceptive Device (IUD) for contraception. An initiative by the International Federation of Gynecology and Obstetrics (FIGO) has been in progress since 2015 resulting in escalated method uptake in implementing hospitals. This study investigates failure rate, complications, and risk factors for one-year continuation of TCu380A IUD when used for immediate postpartum contraception under the initiative in Tanzania. Methodology: A prospective cohort study of women who had TCu380A insertion within 48 h of delivery in 6 hospitals in Tanzania between 1st December 2017 and 18th April 2018 was conducted. Face to face post insertion interviews were made with 1114 clients before discharge and later through phone calls up to the beginning of 13th month postpartum. Postpartum Intrauterine Device (PPIUD) continuation status, complications, duration of time they stayed with the IUD and the currently used method if PPIUD was discontinued were enquired. The outcome variable was PPIUD continuation at one year of IUD insertion. Data were analyzed using Statistical Product and Service Solutions software (SPSS) for Windows version 20 (IBM SPSS Statistics, Chicago, IL, USA). Results: In total 511(45.8%)clients had consented and availed to complete the one-year follow-up. Out of these, 440 still had IUD, giving a one-year continuation rate of 86.1%. Most (63%) IUD discontinuations occurred in the period between 7th week and 6 months of insertion. One-year method expulsion rate was 2.1%. There was one reported pregnancy that gives a method failure rate of about 2 per 1000. The independent risk factors in favor of method continuation at one year were absence of medical or social problem, being a youth (16–24 years), and delivery by Cesarean section. Conclusions: The continuation rate when CuT380A is used for immediate postpartum contraception is high, with low complication and failure rates. Some medical and social factors are important for method continuation, hence the need to consider in training, counselling and advocacy. Keywords: Immediate postpartum, Contraception, Copper T380A, Complications, Tanzania
* Correspondence: [email protected] 2 Department of Obstetrics & Gynecology, Muhimbili University of Health and Allied Sciences (MUHAS), P.O.Box 7623, Dar es Salaam, Tanzania Full list of author information is available at the end of the article © The Author(s). 2020 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate
Data Loading...