Accuracy of the posterior corneal elevation values of Pentacam HR from different reference surfaces in early ectasia diagnosis Rania Serag Elkitkat
. Hesham Mohamed Gharieb . Ihab Saad Othman
Received: 19 March 2020 / Accepted: 5 October 2020 Springer Nature B.V. 2020
Abstract Purpose Detecting the accuracy of various posterior elevation (PE) indices of Pentacam HR, and correlating them with some possibly related factors or parameters, in a cohort with early keratoconus (KC). Methods A cross sectional study that was conducted at Eye World Hospital, Egypt. One hundred and two corneas were enrolled, including two groups; group 1 (50 corneas) having forme fruste or early KC, and group 2 (52 corneas) for healthy controls. Corneas were scanned using Pentacam HR (Oculus, Wetzlar, Germany). The investigated PE parameters were: PE from best fit sphere (BFS), PE from best fit toric ellipsoid (BFTE), PE from exclusion map of Belin Ambrosio’s display (BAD), and PE from difference map of BAD. The four PE values were correlated to age, thinnest corneal thickness ‘‘TCT,’’ posterior aberrations, and posterior Q value. R. S. Elkitkat (&) H. M. Gharieb Faculty of Medicine, Ain Shams University, Cairo 11799, Egypt e-mail: [email protected]; [email protected]
Results All the investigated indices were significantly different in group 1 compared to group 2 (p \ 0.001). Accuracy of PE parameters revealed the highest AUROC for PE from BFTE (AUROC = 0.989, and best cutoff [ 4 um with sensitivity 96.00% and specificity 96.15%). PE from difference map was the least accurate. Correlation coefficients showed a significant correlation between all the studied PE parameters and some of the posterior aberrations (root mean square of higher order aberrations, vertical coma, and spherical aberrations), besides a significant correlation with posterior Q value. Conclusion PE indices are sensitive detectors of early ectasia. PE from BFTE had the highest deduced AUROC. Alterations in PE values can significantly alter many posterior corneal aberrations and the posterior Q. Keywords Pentacam HR indices Early KC detection Posterior elevation Pentacam HR Posterior elevation from Belin Ambrosio display Accuracy of Pentacam posterior elevation
R. S. Elkitkat Al Watani Eye Hospitals, Cairo, Egypt
Introduction H. M. Gharieb I. S. Othman Eye World Hospital, Dokki, Giza, Egypt I. S. Othman Faculty of Medicine, Cairo University, Giza, Egypt
Keratoconus (KC) is a corneal non-inflammatory ectatic condition, which is sometimes associated with
123
Int Ophthalmol
predisposing factors, most commonly frequent eye rubbing [1]. Being a progressive condition, it has a deleterious impact on vision and hence on patients’ quality of life [2]. Early detection of KC aids in earlier treatment interventions, and hence halting the disease and aborting deterioration of the progressive corneal topographic and tomographic changes [3]. Proper corneal assessment for detecting subtle