Could we reduce adhesions to the intra-abdominal mesh in the first week? Experimental study with different methods of fi
- PDF / 954,360 Bytes
- 7 Pages / 595.276 x 790.866 pts Page_size
- 15 Downloads / 184 Views
ORIGINAL ARTICLE
Could we reduce adhesions to the intra‑abdominal mesh in the first week? Experimental study with different methods of fixation J. M. Suárez‑Grau1 · C. Rubio Chaves2 · S. Morales‑Conde2 · C. Mendez García3 · F. Docobo Durantez2 · F. J. Padillo Ruiz2 Received: 18 February 2019 / Accepted: 7 July 2019 © Springer-Verlag France SAS, part of Springer Nature 2019
Abstract Background Adhesion formation is a major problem when a mesh is exposed to intraabodminal viscera, with potential severe complications (bowel occlusion, fistulas or abscesses). New methods for preventing adhesions from a polypropylene mesh placed intra-abdominally or to solve difficult situations, such as when the peritoneum cannot be closed during a TAPP repair for an inguinal hernia, are still being seeked. This study mimics in an animal model a situation that can be found in clinical practice during laparoscopic inguinal hernioplasty. A polypropylene mesh could be exposed to the intra-abdominal cavity even when the peritoneum is closed due to different circumstances, with no options to guarantee the prosthetic material of being exposed to the intrabdominal viscera. Different options have been suggested to solve these situations, being proposed in this study to cover the visceral surface of the mesh with an absorbable sponge containing thrombin, fibrinogen, and clotting factors (Tachosil®, Nycomed, Takeda, Osaka, Japan), to assess its use as a barrier to prevent postoperative adhesion formation. Material and methods Thirty Wistar white rats (300–450 mg) were included in this study as experimental animals, being randomized into three groups (A, B, and C). We performed a bilateral prosthetic repair with conventional polypropylene mesh (2 × 2 cm, 82 kD). Prosthesis fixation was performed as follows. Group A: absorbable suture; group B: metal staples; group C: metal tackers. A piece of insulating absorbable sponge ( Tachosil® 5 × 5 cm) was placed to cover the visceral surface of mesh placed at the right side of each animal. After 10 days, we performed a gross examination (by laparoscopy and laparotomy), measuring the quantity and the quality of the adhesions. Samples were taken for histopathological analysis. Results Tachosil®-treated prostheses showed a statistically significant decrease in the quality of the adhesion found (p 80%. ANOVA, parametric tests and t tests were used for global analysis and comparing adhesions in coated vs. non-coated repairs. The intergroup analysis was performed using Wilcoxon’s non-parametric test for paired samples. Statistical significance was considered when p
Data Loading...