Development, diagnostic performance, and interobserver agreement of a 18 F-flurpiridaz PET automated perfusion quantitat

  • PDF / 1,773,296 Bytes
  • 11 Pages / 593.972 x 792 pts Page_size
  • 61 Downloads / 181 Views

DOWNLOAD

REPORT


b

c d

e f

Division of Cardiology, Department of Medicine, David Geffen School of Medicine, University of California, Los Angeles, CA Department of Radiology and Imaging Sciences, Emory University Hospital, Emory University School of Medicine, Atlanta, GA Syntermed, Inc., Atlanta, GA Department of Biostatistics, Fielding School of Public Health, University of California, Los Angeles, CA Lantheus Medical Imaging, North Billerica, MA Nuclear Medicine Clinic, Department of Molecular and Medical Pharmacology, David Geffen School of Medicine, University of California, Los Angeles, CA

Received Jul 20, 2020; accepted Jul 27, 2020 doi:10.1007/s12350-020-02335-6

Background. Computerized methodologies standardize the myocardial perfusion imaging (MPI) interpretation process. Methods. To develop an automated relative perfusion quantitation approach for 18Fflurpiridaz, PET MPI studies from all phase III trial participants of 18F-flurpiridaz were divided into 3 groups. Count distributions were obtained in N = 40 normal patients undergoing pharmacological or exercise stress. Then, N = 90 additional studies were selected in a derivation group. Following receiver operating characteristic curve analysis, various standard deviations below the mean normal were used as cutoffs for significant CAD, and interobserver variability determined. Finally, diagnostic performance was compared between blinded visual readers and blinded derivations of automated relative quantitation in the remaining N = 548 validation patients. Results. Both approaches yielded comparable accuracies for the detection of global CAD, reaching 71% and 72% by visual reads, and 72% and 68% by automated relative quantitation, when using CAD ‡ 70% or ‡ 50% stenosis for significance, respectively. Similar results were observed when analyzing individual coronary territories. In both pharmacological and exercise stress, automated relative quantitation demonstrated significantly more interobserver agreement than visual reads.

The authors of this article have provided a PowerPoint file, available for download at SpringerLink, which summarises the contents of the paper and is free for re-use at meetings and presentations. Search for the article DOI on SpringerLink.com. Electronic supplementary material The online version of this article (https://doi.org/10.1007/s12350-020-02335-6) contains supplementary material, which is available to authorized users.

Reprint requests: Rene´ R. Sevag Packard, MD, PhD, Division of Cardiology, Department of Medicine, David Geffen School of Medicine, University of California, Los Angeles, CA; rpackard@ mednet.ucla.edu 1071-3581/$34.00 Copyright Ó 2020 American Society of Nuclear Cardiology.

Packard et al Flurpiridaz MPI automated quantitation

Journal of Nuclear CardiologyÒ

Conclusions. Our automated method of 18F-flurpiridaz relative perfusion analysis provides a quantitative, objective, and highly reproducible assessment of PET MPI in normal and CAD subjects undergoing either pharmacological or exercise stress. (J Nucl Cardiol 2020) Ke