Diagnostic accuracy of anti‑phospholipase A2 receptor (PLA2R) antibodies in idiopathic membranous nephropathy: an Italian experience Brunetta Porcelli1,2   · Andrea Guarnieri3 · Fabio Ferretti4 · Guido Garosi3 · Lucia Terzuoli1,2 · Francesca Cinci1,2 · Antonella Tabucchi1,2 · Marilina Tampoia5 · Letizia Abbracciavento5 · Chiara Villani6 · Gaia Deleonardi7 · Ana Gabriela Grondona7 · Marcello Mazzolini8 · Gaetano La Manna9,10 · Marisa Santostefano11 · Maria Infantino12 · Mariangela Manfredi12 · Giuseppe Spatoliatore13 · Alberto Rosati13 · Chiara Somma14 · Nicola Bizzaro15 Received: 23 April 2020 / Accepted: 10 October 2020 © The Author(s) 2020

Abstract Background  Autoantibodies against-phospholipase A2 receptor (PLA2R) are specific markers of idiopathic membranous nephropathy (iMN). Enzyme-linked immunosorbent assay (ELISA) is becoming the preferred method in many laboratories for the determination of anti-PLA2R antibodies, because it provides quantitative results, and is not prone to subjective interpretation, as is the case with indirect immunofluorescence assay. Methods  The purpose of our study was to determine the diagnostic performance of serum PLA2R antibodies detected by commercially available ELISA in a large Italian multicenter cohort of patients with biopsy-proven iMN and in patients with other renal diseases, with special focus on evaluating the optimal cut-off value to discriminate positive and negative results. A total of 495 consecutive patients were recruited. Renal biopsies were performed in all patients, and blood samples were taken before the initiation of immunosuppressive treatment. Results  According to the clinical diagnosis and to kidney biopsy, 126 patients were diagnosed with iMN and 369 had other non-membranous nephropathies. Anti-PLA2R autoantibodies were detected using a commercial anti-PLA2R ELISA. At a cut-off value of 20 relative units (RU)/ml indicated by the manufacturer for positive classification, sensitivity was 61.1% and specificity 99.7%. At a cut-off value of 14 RU/ml indicated by the manufacturer for borderline results, sensitivity was 63.5% and specificity remained the same (99.7%). At a cut-off of 2.7 RU/ml, selected as the optimal cut-off on the basis of ROC curve analysis, sensitivity was 83.3% and specificity 95.1%. The best overall efficiency of the test was observed at 2.7 RU/ ml; however, the highest positive likelihood ratio and diagnostic odds ratio were achieved at 14 RU/ml. A cut-off threshold higher than 14 RU/ml or lower than 2.7 RU/ml entailed worse test performance. Conclusion  Depending on the clinical use (early diagnosis or as a support to confirm clinical diagnosis), nephrologists may take advantage of this evidence by choosing the most convenient cut-off. However, renal biopsy remains mandatory for the definitive diagnosis of iMN and for the assessment of disease severity. Keywords  Anti-phospholipase A2 receptor (PLA2R) autoantibodies · Membranous nephropathy · Cut-off value · Enzymelinked immunosorbent assay (ELISA)

Introduction

* B

Data Loading...