Film Thickness Monitor for CMP Processing
- PDF / 2,530,600 Bytes
- 11 Pages / 417.6 x 639 pts Page_size
- 95 Downloads / 190 Views
Noriyuki Kondo Research Lab., Dainippon Screen Mfg. Co., Ltd., Japan
Contributors:
Takahisa Hayashi*, Hitoshi Atsuta*, Masahiro Horie*, Masao Yoshida**, Norio Kimura**, Manabu Tsujimura**, Hiroyuki Yano***, Katsuya Okumura* * * *Research Lab., Dainippon Screen Mfg. Co., Ltd., Kamikyo-ku, Kyoto, Japan "*Precision Machinery Group, Ebara Co., Ltd., Fujisawa, 251, Japan ***Microelectronics Engineering Lab., Toshiba Co., Ltd., Isogoku,Yokohama, Japan
ABSTRACT In the CMP planarization process, detecting the final polishing point is extremely important for maintaining high yield rates. Therefore, various methods for detecting the final polishing point have been developed. We consider it vital that the SiO 2 film thickness across a representative area be measured extremely precisely at high speed in the final stages to accurately control film polishing. However, up until now there has not been any wholly satisfactory method to achieve this. In order to measure a fine representative film area (test pattern) both rapidly and accurately, we concluded that the non-contact, non-destructive and highly reliable methods of
spectrometric analysis were most promising. Based on these considerations, we developed a compact spectrometric film thickness measurement system which can accurately inspect test patterns at high speeds and installed it adjacent to the CMP equipment's polishing table. Using this system as a film thickness monitor, we can now measure film thickness while rinsing away slurry contaminants, halt polishing at any stage, and calculate the remaining polishing time from the current and desired thicknesses. This system's pattern identification function can automatically measure the film thickness with very fine test patterns (as small as 40 square microns). When used with SiO 2 single layer films, the experimental prototype's measurements proved reliably reproducible (showing a deviation of less than 4 nm at 3 a over repeated trials), and required thirty seconds or less per wafer (including time for pre-alignment and five-point measurement). The system's theoretical basis and actual operations are described below.
233
Mat. Res. Soc. Symp. Proc. Vol. 566 ©2000 Materials Research Society
CONCEPT OF FINAL POLISHING POINT CONTROL By accurately measuring the film thickness at the points defined by test patterns just before the completion of wafer polishing, we can precisely calculate the amount still to be polished and thus the remaining polishing time. To facilitate this analysis, the optical head and measurement unit have been installed next to the polishing table. The measurement unit includes a slurry rinsing function, a patternmatching auto-alignment function, and a compact alignment stage. Since wafers are measured while held in the top ring of the CMP equipment, polishing can be re-started as soon as a measurement is completed. The experimental prototype is called the "CMP Semi-InSitu Monitor".
FILM THICKNESS MEASUREMENT When a sample wafer surface is irradiated with light, multiple reflections occur at the p