Incremental diagnostic value of [ 18 F]tetrafluoroborate PET-CT compared to [ 131 I]iodine scintigraphy in recurrent dif

  • PDF / 492,923 Bytes
  • 8 Pages / 595.276 x 790.866 pts Page_size
  • 88 Downloads / 177 Views

DOWNLOAD

REPORT


ORIGINAL ARTICLE

Incremental diagnostic value of [18F]tetrafluoroborate PET-CT compared to [131I]iodine scintigraphy in recurrent differentiated thyroid cancer Matthias Dittmann 1 & José Manuel Gonzalez Carvalho 1 & Kambiz Rahbar 1 & Michael Schäfers 1,2,3 & Michael Claesener 1 & Burkhard Riemann 1 & Robert Seifert 1,2 Received: 15 January 2020 / Accepted: 14 February 2020 # The Author(s) 2020

Abstract Introduction Efficient therapy of recurrent differentiated thyroid cancer (DTC) is dependent on precise molecular imaging techniques targeting the human sodium iodide symporter (hNIS), which is a marker both of thyroid and DTC cells. Various iodine isotopes have been utilized for detecting DTC; however, these come with unfavorable radiation exposure and image quality ([131I]iodine) or limited availability ([124I]iodine). In contrast, [18F]tetrafluoroborate (TFB) is a novel radiolabeled PET substrate of hNIS, results in PET images with high-quality and low radiation doses, and should therefore be suited for imaging of DTC. The aim of the present study was to compare the diagnostic performance of [18F]TFB-PET to the clinical reference standard [131I]iodine scintigraphy in patients with recurrent DTC. Methods Twenty-five patients with recurrent DTC were included in this retrospective analysis. All patients underwent [18F]TFBPET combined with either CT or MRI due to newly discovered elevated TG levels, antiTG levels, sonographically suspicious cervical lymph nodes, or combinations of these findings. Correlative [131I]iodine whole-body scintigraphy (dxWBS) including SPECT-CT was present for all patients; correlative [18F]FDG-PET-CT was present for 21 patients. Histological verification of [18F]TFB positive findings was available in 4 patients. Results [18F]TFB-PET detected local recurrence or metastases of DTC in significantly more patients than conventional [131I]iodine dxWBS and SPECT-CT (13/25 = 52% vs. 3/25 = 12%, p = 0.002). The diagnosis of 6 patients with cervical lymph node metastases that showed mildly increased FDG metabolism but negative [131I]iodine scintigraphy was changed: [18F]TFBPET revealed hNIS expression in the metastases, which were therefore reclassified as only partly de-differentiated (histological confirmation present in two patients). Highest sensitivity for detecting recurrent DTC had the combination of [18F]TFB-PET-CT/ MRI with [18F]FDG-PET-CT (64%). Conclusion In the present cohort, [18F]TFB-PET shows higher sensitivity and accuracy than [131I]iodine WBS and SPECT-CT in detecting recurrent DTC. The combination of [18F]TFB-PET with [18F]FDG-PET-CT seems a reasonable strategy to characterize DTC tumor manifestations with respect to their differentiation and thereby also individually plan and monitor treatment. Future prospective studies evaluating the potential of [18F]TFB-PET in recurrent DTC are warranted. Keywords Thyroid cancer . Tetrafluoroborate . Iodine . PET-CT . SPECT . WBS This article is part of the Topical Collection on Oncology – Head and Neck * Robert Seifert robert.seifert@uni-mu