Muscle strength but not balance improves after arthroscopic biodegradable polyurethane meniscus scaffold application
- PDF / 1,230,015 Bytes
- 9 Pages / 595.276 x 790.866 pts Page_size
- 66 Downloads / 176 Views
ORIGINAL ARTICLE
Muscle strength but not balance improves after arthroscopic biodegradable polyurethane meniscus scaffold application M. Akkaya1 · S. Gursoy1 · N. Ozberk2 · M. E. Simsek3 · F. Korkusuz4 · M. Bozkurt1 Received: 9 January 2020 / Accepted: 7 September 2020 © Istituto Ortopedico Rizzoli 2020
Abstract Purpose This study aimed to assess the impact of biodegradable polyurethane meniscus scaffold implantation (BPMSI) on muscle strength and balance in comparison with the healthy contralateral knee in patients with irreparable medial meniscus defect. Methods This observational and prospective case-cohort study was conducted with patients who had irreparable meniscal defects and underwent arthroscopic meniscus scaffold implantation. Surgeries were carried out on the medial meniscus of 16 right and 4 left knees. Visual analog scale (VAS) was used to assess the degree of pain relief. Knee Injury and Osteoarthritis Outcome Score (KOOS) and Lysholm (LYS) score were used to evaluate the functional improvement at weeks 12, 24 and 36. Concentric and eccentric quadriceps and hamstring peak torque (PT) as well as the peak torque-to-body weight (PTB) ratio, anterior–posterior, mediolateral and overall stability indexes were assessed at the same time points. Results Twenty male patients with a mean age and body mass index of 32.2 ± 8.8 years and 26.2 ± 4.2 kg/m2, respectively, were included in the study. The amount of pain decreased from 7.6 ± 1.5% to 2.9 ± 1.5% at postoperative week 36. Range of motion, Lysholm score and KOOS increased from 87.0ο ± 9.5ο to 115.0ο ± 15.1ο, 30.8 ± 4.3 to 81.5 ± 5.3 and 37.4 ± 5.3 to 74.1 ± 7.2, respectively. Concentric quadriceps and hamstring peak torque values and peak torque/body weight ratios were improved in the knees that received a meniscus scaffold implant. Anterior/posterior, medial/lateral, and overall stability indexes with or without biofeedback exhibited a slight improvement, which was not statistically significant. Conclusion BPMSI led to decreased pain and improved function at postoperative week 36. Although muscle strength almost returned to normal, balance parameters did not recover within 36 weeks after the procedure. Keywords Meniscus · Implant · Polyurethane scaffold · Muscle strength · Balance
Introduction
* M. Akkaya [email protected] 1
Department of Orthopedics and Traumatology, Ankara Yildirim Beyazit University Medical Faculty, Ankara Yildirim Beyazit University, 06100 Ankara, Turkey
2
Department of Physical Treatment and Rehabilitation, Middle East Technical University Medical Center, 06100 Ankara, Turkey
3
Department of Orthopedics and Traumatology, Lokman Hekim University, 06100 Ankara, Turkey
4
Department of Sports Medicine, Hacettepe University Medical Faculty, 06800 Ankara, Turkey
Biodegradable polyurethane meniscus scaffolds (Actifit®— Orteq Sports Medicine, Wimbledon, London, UK) are arthroscopically implantable medical devices which reduce symptoms, improve function, maintain knee stability, restore biomechanics, and protect ca
Data Loading...