Assessment of the efficacy of early phase parameters by 123 I-MIBG dynamic imaging for distinguishing Lewy body-related

  • PDF / 344,425 Bytes
  • 8 Pages / 595.276 x 790.866 pts Page_size
  • 19 Downloads / 149 Views

DOWNLOAD

REPORT


ORIGINAL ARTICLE

Assessment of the efficacy of early phase parameters by 123 I-MIBG dynamic imaging for distinguishing Lewy body-related diseases from Parkinson’s syndrome Takuro Shiiba • Ryuichi Nishii • Masayuki Sasaki Yasushi Kihara • Kazuhito Tsuruta • Masaji Maeda • Junji Morishita



Received: 11 May 2014 / Accepted: 18 October 2014 Ó The Japanese Society of Nuclear Medicine 2014

Abstract Objective The aim of this study was to assess the efficacy of early phase washout rate (early WR) and area under the time–activity curve (AUTAC) by 123I-metaiodobenzylguanidine (MIBG) dynamic chest imaging for distinguishing Lewy body-related diseases (LBRD) from Parkinson’s syndrome (PS) and reducing examination time. Methods Sixty-two patients with suspected LBRD who underwent 123I-MIBG dynamic imaging in early phase were retrospectively selected. The early WR and AUTAC were calculated from 123I-MIBG dynamic data of the heart. We evaluated the relationships between proposed and T. Shiiba (&)  M. Maeda Department of Radiological Technology, Koga General Hospital, 1749-1 Sudaki, Ikeuchi-Cho, Miyazaki 880-0041, Japan e-mail: [email protected] T. Shiiba Department of Health Sciences, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-Ku, Fukuoka 812-8582, Japan R. Nishii Department of Radiology, University of Miyazaki, 5200 Kihara, Kiyotake-Cho, Miyazaki 889-1692, Japan M. Sasaki  J. Morishita Department of Health Sciences, Faculty of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-Ku, Fukuoka 812-8582, Japan Y. Kihara Department of Radiology, Koga General Hospital, 1749-1 Sudaki, Ikeuchi-Cho, Miyazaki 880-0041, Japan K. Tsuruta Department of Neurology, Junwakai Memorial Hospital, 1119 Komatsu, Miyazaki 880-2112, Japan

conventional parameters by using Spearman’s rank correlation coefficient. Differences in parameters between LBRD and PS groups were tested for statistical significance using the Mann–Whitney U test. The diagnostic performance of all parameters for distinguishing LBRD from PS was assessed in terms of receiver operating characteristic (ROC) analysis. Additionally, combination diagnostic performance and concordance rate between early phase parameters and late H/M ratio by kappa statistics were also assessed. Results The early WR and AUTAC showed a positive and negative correlation with conventional parameters. Both the early WR and AUTAC of LBRD group were significantly distinguishable from those of the PS group (p \ 0.001). Area under the ROC curve of the early WR (0.98) was greater than that of AUTAC (0.91). The diagnostic performance of combination of the early phase parameters was 93 % sensitivity and 100 % specificity. Moreover, the early phase parameters showed excellent agreement with late H/M ratio (k = 0.93). Conclusions The early WR and AUTAC showed high performance for distinguishing LBRD from PS, and the combination diagnosis with early H/M ratio and early WR contribute to improve the diagnostic performance. Thus, these parameters would be useful for reduc