Novel Single and Multiple Shell Uniform Sampling Schemes for Diffusion MRI Using Spherical Codes
A good data sampling scheme is important for diffusion MRI acquisition and reconstruction. Diffusion Weighted Imaging (DWI) data is normally acquired on single or multiple shells in q-space. The samples in different shells are typically distributed unifor
- PDF / 232,728 Bytes
- 9 Pages / 439.363 x 666.131 pts Page_size
- 96 Downloads / 174 Views
2
Section on Tissue Biophysics and Biomimetics (STBB), PPITS, NICHD, NIBIB Department of Radiology and BRIC, University of North Carolina at Chapel Hill, USA [email protected]
Abstract. A good data sampling scheme is important for diffusion MRI acquisition and reconstruction. Diffusion Weighted Imaging (DWI) data is normally acquired on single or multiple shells in q-space. The samples in different shells are typically distributed uniformly, because they should be invariant to the orientation of structures within tissue, or the laboratory coordinate frame. The Electrostatic Energy Minimization (EEM) method, originally proposed for single shell sampling scheme in dMRI by Jones et al., was recently generalized to the multi-shell case, called generalized EEM (GEEM). GEEM has been successfully used in the Human Connectome Project (HCP). Recently, the Spherical Code (SC) concept was proposed to maximize the minimal angle between different samples in single or multiple shells, producing a larger angular separation and better rotational invariance than the GEEM method. In this paper, we propose two novel algorithms based on the SC concept: 1) an efficient incremental constructive method, called Iterative Maximum Overlap Construction (IMOC), to generate a sampling scheme on a discretized sphere; 2) a constrained non-linear optimization (CNLO) method to update a given initial scheme on the continuous sphere. Compared to existing incremental estimation methods, IMOC obtains schemes with much larger separation angles between samples, which are very close to the best known solutions in single shell case. Compared to the existing Riemannian gradient descent method, CNLO is more robust and stable. Experiments demonstrated that the two proposed methods provide larger separation angles and better rotational invariance than the state-of-the-art GEEM and methods based on the SC concept.
1 Introduction Diffusion MRI (dMRI) is a unique imaging technique to explore microstructure properties of white matter in the human brain by mapping local diffusion of water molecules. In dMRI, one obtains a limited number of samples of the 3D diffusion signal attenuation E(q) in q-space. Reconstruction in dMRI is to recover the continuous E(q) from these scanned measurements and to estimate some meaningful quantities including the diffusion tensor, the Ensemble Average Propagator (EAP), etc. An appropriate sampling scheme in q-space is important for all dMRI acquisition and reconstruction applications in order to recover as much information as possible using a minimal number of measurements. It is infeasible to develop a general optimal sampling scheme that works best for all signal types and all reconstruction methods. However, a necessary property for an optimal sampling scheme is that the samples should be spherically uniformly c Springer International Publishing Switzerland 2015 N. Navab et al. (Eds.): MICCAI 2015, Part I, LNCS 9349, pp. 28–36, 2015. DOI: 10.1007/978-3-319-24553-9_4
Sampling Schemes for Diffusion MRI Using Spherical Code
Data Loading...