Two-side slug-flow microextraction coupled with ion mobility spectrometry for fast quantification of amphetamine and met
- PDF / 844,777 Bytes
- 9 Pages / 595.276 x 790.866 pts Page_size
- 55 Downloads / 147 Views
ORIGINAL RESEARCH
Two-side slug-flow microextraction coupled with ion mobility spectrometry for fast quantification of amphetamine and methamphetamine in human urine Majid Behpour 1 & Saeed Nojavan 1
&
Zahra Ghaniyari 1
Received: 25 June 2020 / Revised: 13 September 2020 / Accepted: 16 September 2020 / Published online: 19 October 2020 # Springer-Verlag GmbH Germany, part of Springer Nature 2020
Abstract In this study, first time a novel slug-flow microextraction (SFME) procedure named two-side SFME was developed and followed by ion mobility spectrometry equipped with corona discharge source (CD-IMS) for quantification of two abused drugs (amphetamine (AM) and methamphetamine (ME)) in urine samples. Regarding technique workflow, the organic extraction solvent (10 μL) was sandwiched between two portions of aqueous sample solution (the volume of each portion of sample solution was 5 μL) into a disposable glass capillary tube. The extraction of analytes was performed via the slug flows induced by the movements of the three liquids, which was conducted by tilting the glass capillary tube for several cycles. Finally, the extraction solvent was collected by a microsyringe and then injected (5 μL) into the CD-IMS. The effects of the effective parameters, including type of extraction solvent, number of tilting the glass capillary tube, and concentration of salt in sample solution were investigated. Under the optimized extraction condition (organic solvent: toluene; number of tilting the glass capillary tube: 10 times; concentration of salt: 5% (w/v)), the proposed two-side SFME/CD-IMS provided good linearity with coefficients of determination ≥0.993 over a concentration range of 25.0–2000.0 ng mL−1. Accordingly, acceptable limits of detection (S/N = 3) were 10.0 and 2.5 ng mL−1 for AM and ME, respectively. Furthermore, acceptable recoveries were ≥ 81.5, and ≥ 88.0% for AM and ME in a human urine sample, respectively, while repeatability and reproducibility ranged from 6.7 to 14.7% (n = 3). Keywords Amphetamine . Corona discharge ionization-ion mobility spectrometry . Human urine . Methamphetamine . Two-side slug-flow microextraction
Introduction Today, drug abuse is a growing global social problem. From 2009 to 2012, the occurrence of drug abuse, including opioid, cocaine, and amphetamine (AM) drugs, was 5.2% in the 15to 64-year-old population. Later in 2013, the researches were done for 12 years old up in the United States, and the results were confirmed for 9.4% of the population [1]. Illegal substances affect youth, who takes drugs for recreational destinations, and it leads to many social problems such as child abuse, murder, and suicide [2]. Routine analysis of abused drugs has insignificant selectivity, and it might cause a wrong
* Saeed Nojavan [email protected] 1
Department of Analytical Chemistry and Pollutants, Shahid Beheshti University, G. C., Evin, Tehran 1983969411, Iran
conclusion, also it is incapable of distinguish different types of drugs (e.g., AM and methamphetamine (ME)) [3]. So, a reliable me