Virtual monoenergetic images from spectral detector computed tomography facilitate washout assessment in arterially hype

  • PDF / 2,459,169 Bytes
  • 10 Pages / 595.276 x 790.866 pts Page_size
  • 39 Downloads / 127 Views

DOWNLOAD

REPORT


HEPATOBILIARY-PANCREAS

Virtual monoenergetic images from spectral detector computed tomography facilitate washout assessment in arterially hyper-enhancing liver lesions R. P. Reimer 1 & N. Große Hokamp 1 & A. Fehrmann Efferoth 1 & A. Krauskopf 2 & D. Zopfs 1 & J. R. Kröger 1 & T. Persigehl 1 & D. Maintz 1 & A. C. Bunck 1 Received: 27 March 2020 / Revised: 20 August 2020 / Accepted: 6 October 2020 # The Author(s) 2020

Abstract Objectives To investigate whether the increased soft tissue contrast of virtual monoenergetic images (VMIs) obtained from a spectral detector computed tomography (SDCT) system improves washout assessment of arterially hyper-enhancing liver lesions. Methods Fifty-nine arterially hyper-enhancing lesions in 31 patients (age 65 ± 9 years, M/W 20/11) were included in this IRBapproved study. All patients underwent multi-phase SDCT for HCC screening. MRI, CEUS or biopsy within 3 months served as standard of reference to classify lesions as LiRADS 3 or 4/5. VMIs and conventional images (CIs) were reconstructed. Visual analysis was performed on 40, 60, and 80 kiloelectronvolt (keV) and CIs by 3 radiologists. Presence and visibility of washout were assessed; image quality and confidence of washout evaluation were evaluated on 5-point Likert scales. Signal-to-noise ratio (SNR), lesion-to-liver contrast-to-noise ratio (CNR) (|HUlesion–HUliver|/SDliver) and washout (|HUlesion–HUliver|) were calculated. Statistical assessment was performed using ANOVA and Wilcoxon test. Results On subjective lesion analysis, the highest level of diagnostic confidence and highest sensitivity for the detection of lesion washout were found for 40-keV VMIs (40 keV vs. CI, 81.3 vs. 71.3%). Image quality parameters were significantly better in lowkiloelectronvolt VMIs than in CIs (p < 0.05; e.g. SNRliver: 40 keV vs. CIs, 12.5 ± 4.1 vs. 5.6 ± 1.6). In LiRADS 4/5 lesions, CNR and quantitative washout values were significantly higher in 40-keV VMIs compared to CIs (p < 0.05; e.g. CNR and washout in 40 keV vs. CIs, 2.3 ± 1.6 vs. 0.8 ± 0.5 and 29.0 ± 19.1 vs. 12.9 ± 6.9 HU, respectively). Conclusion By increasing lesion contrast, low-kiloelectronvolt VMIs obtained from SDCT improve washout assessment of hyper-enhancing liver lesions with respect to washout visibility and diagnostic confidence. Key Points • Low-kiloelectronvolt virtual monoenergetic images from spectral detector CT facilitate washout assessment in arterially hyperenhancing liver lesions. • Image quality and quantitative washout parameters as well as subjective washout visibility and diagnostic confidence benefit from low-kiloelectronvolt virtual monoenergetic images. Keywords Carcinoma, hepatocellular . Tomography, X-ray computed . Diagnostic imaging

Electronic supplementary material The online version of this article (https://doi.org/10.1007/s00330-020-07379-3) contains supplementary material, which is available to authorized users. * R. P. Reimer [email protected] 1

Department of Diagnostic and Interventional Radiology, Faculty of Medicine and University