Advanced zoomed diffusion-weighted imaging vs. full-field-of-view diffusion-weighted imaging in prostate cancer detectio
- PDF / 1,144,831 Bytes
- 10 Pages / 595.276 x 790.866 pts Page_size
- 16 Downloads / 169 Views
IMAGING INFORMATICS AND ARTIFICIAL INTELLIGENCE
Advanced zoomed diffusion-weighted imaging vs. full-field-of-view diffusion-weighted imaging in prostate cancer detection: a radiomic features study Lei Hu 1 & Da wei Zhou 2 & Cai xia Fu 3 & Thomas Benkert 4 & Chun yu Jiang 1 & Rui ting Li 1 & Li ming Wei 1 & Jun gong Zhao 1 Received: 25 March 2020 / Revised: 16 July 2020 / Accepted: 26 August 2020 # European Society of Radiology 2020
Abstract Objectives We aimed to compare the efficiency of prostate cancer (PCa) detection using a radiomics signature based on advanced zoomed diffusion-weighted imaging and conventional full-field-of-view DWI. Methods A total of 136 patients, including 73 patients with PCa and 63 without PCa, underwent multi-parametric magnetic resonance imaging (mp-MRI). Radiomic features were extracted from prostate lesion areas segmented on full-field-of-view DWI with b-value = 1500 s/mm2 (f-DWIb1500), advanced zoomed DWI images with b-value = 1500 s/mm2 (z-DWIb1500), calculated zoomed DWI with b-value = 2000 s/mm2 (z-calDWIb2000), and apparent diffusion coefficient (ADC) maps derived from both sequences (f-ADC and z-ADC). Single-imaging modality radiomics signature, mp-MRI radiomics signature, and a mixed model based on mp-MRI and clinically independent risk factors were built to predict PCa probability. The diagnostic efficacy and the potential net benefits of each model were evaluated. Results Both z-DWIb1500 and z-calDWIb2000 had significantly better predictive performance than f-DWIb1500 (z-DWIb1500 vs. f-DWIb1500: p = 0.048; z-calDWIb2000 vs. f-DWIb1500: p = 0.014). z-ADC had a slightly higher area under the curve (AUC) value compared with f-ADC value but was not significantly different (p = 0.127). For predicting the presence of PCa, the AUCs of clinical independent risk factors model, mp-MRI model, and mixed model were 0.81, 0.93, and 0.94 in training sets, and 0.74, 0.92, and 0.93 in validation sets, respectively. Conclusion Radiomics signatures based on the z-DWI technology had better diagnostic accuracy for PCa than that based on the fDWI technology. The mixed model was better at diagnosing PCa and guiding clinical interventions for patients with suspected PCa compared with mp-MRI signatures and clinically independent risk factors. Key Points • Advanced zoomed DWI technology can improve the diagnostic accuracy of radiomics signatures for PCa. • Radiomics signatures based on z-calDWIb2000 have the best diagnostic performance among individual imaging modalities. • Compared with the independent clinical risk factors and the mp-MRI model, the mixed model has the best diagnostic efficiency. Keywords Multi-parametric magnetic resonance imaging . Diffusion magnetic resonance imaging . Prostate cancer . Logistic models . Radiomics
Electronic supplementary material The online version of this article (https://doi.org/10.1007/s00330-020-07227-4) contains supplementary material, which is available to authorized users. * Jun gong Zhao [email protected]
2
State Key Laboratory of Integrat