Computer-Aided Pulmonary Embolism Detection Using a Novel Vessel-Aligned Multi-planar Image Representation and Convoluti

Computer-aided detection (CAD) can play a major role in diagnosing pulmonary embolism (PE) at CT pulmonary angiography (CTPA). However, despite their demonstrated utility, to achieve a clinically acceptable sensitivity, existing PE CAD systems generate a

  • PDF / 1,003,064 Bytes
  • 8 Pages / 439.363 x 666.131 pts Page_size
  • 78 Downloads / 173 Views

DOWNLOAD

REPORT


Department of Biomedical Informatics, Arizona State University, Scottsdale, AZ, USA {Nima.Tajbakhsh,Jianming.Liang}@asu.edu 2 Department of Radiology, Mayo Clinic, Scottsdale, AZ, USA [email protected]

Abstract. Computer-aided detection (CAD) can play a major role in diagnosing pulmonary embolism (PE) at CT pulmonary angiography (CTPA). However, despite their demonstrated utility, to achieve a clinically acceptable sensitivity, existing PE CAD systems generate a high number of false positives, imposing extra burdens on radiologists to adjudicate these superfluous CAD findings. In this study, we investigate the feasibility of convolutional neural networks (CNNs) as an effective mechanism for eliminating false positives. A critical issue in successfully utilizing CNNs for detecting an object in 3D images is to develop a “right” image representation for the object. Toward this end, we have developed a vesselaligned multi-planar image representation of emboli. Our image representation offers three advantages: (1) efficiency and compactness—concisely summarizing the 3D contextual information around an embolus in only 2 image channels, (2) consistency—automatically aligning the embolus in the 2-channel images according to the orientation of the affected vessel, and (3) expandability—naturally supporting data augmentation for training CNNs. We have evaluated our CAD approach using 121 CTPA datasets with a total of 326 emboli, achieving a sensitivity of 83% at 2 false positives per volume. This performance is superior to the best performing CAD system in the literature, which achieves a sensitivity of 71% at the same level of false positives. We have further evaluated our system using the entire 20 CTPA test datasets from the PE challenge. Our system outperforms the winning system from the challenge at 0mm localization error but is outperformed by it at 2mm and 5mm localization errors. In our view, the performance at 0mm localization error is more important than those at 2mm and 5mm localization errors. Keywords: Computer-aided detection, pulmonary embolism, convolutional neural networks, vessel-aligned image representation.

1 Introduction Pulmonary embolism (PE) is a thrombus, occasionally colloquially referred to as a blood clot, that travels from the legs, or rarely other parts of the body, to the lungs where it obstructs central, lobar, segmental, or subsegmental pulmonary arteries depending on the size of the embolus. The untreated mortality rate of PE may approach c Springer International Publishing Switzerland 2015  N. Navab et al. (Eds.): MICCAI 2015, Part II, LNCS 9350, pp. 62–69, 2015. DOI: 10.1007/978-3-319-24571-3_8

Computer-Aided Pulmonary Embolism Detection

63

30%. However, with early diagnosis and treatment, the mortality rate decreases to as low as 2% to 11%. CT pulmonary angiography (CTPA) is the primary means for the evaluation of suspected PE. At CTPA, an embolus appears as a dark region surrounded by the brighter, contrast-enhanced vessel lumen. CTPA dataset interpretation demands a radiolo