Conductive Electrospun and Micro-StereoLithographically Produced Porous Scaffolds as Potential Neural Interface Material

  • PDF / 388,459 Bytes
  • 8 Pages / 432 x 648 pts Page_size
  • 55 Downloads / 170 Views

DOWNLOAD

REPORT


Conductive Electrospun and Micro-StereoLithographically Produced Porous Scaffolds as Potential Neural Interface Materials Shawn M. Dirk1, Kirsten N. Cicotte1,2, Elizabeth L. Hedberg-Dirk2,3, Stephen Buerger4, Patrick P. Lin5, and Gregory Reece6 1

Organic Materials Department, Sandia National Laboratories, Albuquerque, NM 87185, U.S.A. Center for Biomedical Engineering, University of New Mexico, Albuquerque, New Mexico, U.S.A. 3 Chemical and Nuclear Engineering Department, University of New Mexico, Albuquerque, New Mexico, U.S.A. 4 Intelligent System Controls Department, Sandia National Laboratories, Albuquerque, New Mexico, U.S.A. 5 Department of Orthopedic Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas U.S.A. 6 Department of Plastic Surgery, The University of Texas MD Anderson Cancer Center, Houston, Texas, U.S.A. 2

ABSTRACT Our overall intent is to develop improved electrically active prosthetic devices to allow interactions between regenerated nerve fibers (axons) and external electronics. To allow for infiltration of axons, these devices must be highly porous. Additionally, they must exhibit selective and structured conductivity to allow the connection of electrode sites with external circuitry with tunable electrical properties that enable the transmission of neural signals through physical connections to external circuitry (e.g. through attached wires.) The chosen material must be biocompatible with minimal irresolvable inflammatory response to allow intimate contact with regenerated nerve tissue and mechanically compatible with the surrounding nervous tissue. We have utilized electrospinning and projection lithography as tools to create conductive, porous networks of non-woven biocompatible fibers in order to meet the materials requirements for the neural interface. The biocompatible fibers were based on the known biocompatible material poly(dimethyl siloxane) (PDMS) as well as a newer biomaterial material developed in our laboratories, poly(butylene fumarate) (PBF). Both of the polymers cannot be electrospun using conventional electrospinning techniques due to their low glass transition temperatures, so in situ crosslinking methodologies were developed to facilitate micro- and nano-fiber formation during electrospinning. The conductivity of the electrospun fiber mats was controlled by varying the loading with multi-walled carbon nanotubes (MWNTs). INTRODUCTION In 2002 there were 250,000 reported injuries in which damage to peripheral nerves occurred.[1] In 2010, 171 amputations were performed on U.S. soldiers at Landstule airbase in Germany as a result of the conflict in Afghanistan. Of those soldiers, 65 required multiple amputations.[2] Neurally-interfaced prosthetics can potentially be used to provide improved

163

quality of life for those with injured peripheral nerves. Neural interface devices operate at the intersection of the peripheral nervous system and an external system. These interfaces can be used to monitor nerve signals or provide inputs to allow amputees the