Numerical investigation on two-fluid model (micropolar-Newtonian) for pulsatile flow of blood in a tapered arterial sten
- PDF / 1,112,265 Bytes
- 25 Pages / 439.37 x 666.142 pts Page_size
- 77 Downloads / 290 Views
Numerical investigation on two-fluid model (micropolar-Newtonian) for pulsatile flow of blood in a tapered arterial stenosis with radially variable magnetic field and core fluid viscosity R. Ponalagusamy1 · S. Priyadharshini1
Received: 11 December 2015 / Revised: 10 April 2016 / Accepted: 11 July 2016 © SBMAC - Sociedade Brasileira de Matemática Aplicada e Computacional 2016
Abstract In the present study, an unsteady two-fluid model of blood through a tapered arterial stenosis with variable viscosity in the presence of variable magnetic field has been investigated. In this model, blood in the core region is assumed to be micropolar and plasma in the peripheral layer as Newtonian. Finite difference method is employed in solving the governing equations. The solutions for velocity, flow rate, wall shear stress and flow resistance are computed numerically. A comparison between the velocity profiles obtained by the present study and the experimental data is made and a good agreement between them is found. The model is used to study the effect of parameters such as taper angle, radially variable viscosity, hematocrit, the coupling number, the micropolar parameter, magnetic field and plasma layer thickness on physiologically important parameters such as wall shear stress distribution in the stenotic region and flow resistance. The results in the case of constant magnetic field and variable magnetic field are compared to study the effects of magnetic field on the flow of blood. It is found that the magnitudes of wall shear stress and flow resistance are higher in the case of variable magnetic field. It is important to note that the flow resistance is higher for magneto-micropolar fluid than the micropolar fluid. The wall shear stress decreases with increasing hematocrit parameter whereas flow resistance increases with hematocrit when the applied pressure gradient is held fixed. The model clearly shows the situation of a patient with a tapered arterial stenosis under feverish condition. Due care has been taken to compare the present theoretical results with the existing ones including experimental results and good agreement between them has been observed both qualitatively and quantitatively.
Communicated by Florence Hubert.
B
S. Priyadharshini [email protected] R. Ponalagusamy [email protected]
1
Department of Mathematics, National Institute of Technology, Tiruchirappalli 620015, Tamilnadu, India
123
R. Ponalagusamy, S. Priyadharshini
Keywords Micropolar fluid · Finite difference method · Hematocrit · Radially variable Magnetic field · Stenosed artery · Tapered artery Mathematics Subject Classification 92C10
Dimensional z¯ r¯ t¯ R¯ 1 (¯z ) ¯ z) R(¯ ¯ r) k(¯ u¯ c v¯c u¯ p v¯ p v¯θ j¯ p¯ H¯ 02 (¯r )
Axial distance Radial distance Time Radius of the central core region Radius of the artery in the stenotic region Rotational viscosity Axial velocity of the core fluid Radial velocity of the core fluid Axial velocity of plasma Radial velocity of plasma Rotational velocity Micro-gyration parameter Pressure Variable