CT venography correlate of transverse sinus stenosis and venous transstenotic pressure gradient in unilateral pulsatile
- PDF / 370,140 Bytes
- 7 Pages / 595.276 x 790.866 pts Page_size
- 103 Downloads / 151 Views
HEAD AND NECK
CT venography correlate of transverse sinus stenosis and venous transstenotic pressure gradient in unilateral pulsatile tinnitus patients with sigmoid sinus wall anomalies Pengfei Zhao 1 & Heyu Ding 1 & Han Lv 1 & Xiaoshuai Li 1 & Xiaoyu Qiu 1 & Rong Zeng 2 & Guopeng Wang 2 & Jian Wei 3 & Long Jin 3 & Zhenghan Yang 1 & Shusheng Gong 2 & Zhenchang Wang 1 Received: 5 May 2020 / Revised: 30 August 2020 / Accepted: 13 October 2020 # The Author(s) 2020
Abstract Objectives To investigate the correlation between transverse sinus stenosis (TSS) and transstenotic pressure gradient (TPG) in unilateral pulsatile tinnitus (PT) patients with sigmoid sinus wall anomalies (SSWA). Methods Fifty-seven patients with unilateral venous PT were retrospectively included. All of them underwent CT venography and catheter manometry, accompanied with SSWA. The degree, length, shape (intrinsic/extrinsic/dysplasia), location (proximal/ middle/distal, referring to the relative position of TSS and the Labbé vein junction) of TSS, the types of SSWA (dehiscence/ diverticulum), and the degree of transverse sinus outflow laterality were assessed, and the correlations with ipsilesional TPG were analyzed. Results The mean value of ipsilesional TPG was 7.61 ± 0.52 mmHg. The degree and length of ipsilesional TSS were positively correlated with TPG (p < 0.001, p’ < 0.001), respectively. TPG was significantly larger in patients with contralateral transverse sinus dysplasia than those without (p = 0.023) and significantly smaller in patients with ipsilesional sigmoid sinus diverticulum than those with isolated dehiscence (p = 0.001). No statistical difference in TPG was shown between ipsilesional TSSs of different shapes or locations (p > 0.05). No correlation was noted between the degree of ipsilesional transverse sinus outflow laterality and TPG (p = 0.051). Stepwise linear regression indicated that the degree (β = 9.207, 95% CI = 3.558–14.856), length (β = 0.122, 95% CI = 0.025–0.220) of ipsilesional TSS, and contralateral transverse sinus dysplasia (β = 1.875, 95% CI = 0.220– 3.530) were significantly correlated with TPG (R2 = 0.471). Conclusions The degree, length of ipsilesional TSS, and contralateral transverse sinus dysplasia may be used to predict TPG in unilateral PT patients with SSWA. Key Points • CT venography may act as a screening tool to help low-probability unilateral pulsatile tinnitus (PT) patients with sigmoid sinus wall anomalies (SSWA) avoid invasive catheter manometry. • The degree and length of ipsilesional transverse sinus stenosis (TSS) are positively correlated with transtenotic pressure gradient (TPG) in unilateral PT patients with SSWA. • Ipsilesional TPG is larger in unilateral PT patients with contralateral transverse sinus dysplasia than those without and is smaller in unilateral PT patients with sigmoid sinus diverticulum than those with isolated dehiscence. Keywords Tinnitus . Transverse sinuses . Diverticulum . Tomography, X-ray computed
* Shusheng Gong [email protected] * Zhenchang Wang [email protected]
Data Loading...