Field performance of ultrasensitive and conventional malaria rapid diagnostic tests in southern Mozambique

  • PDF / 1,929,084 Bytes
  • 15 Pages / 595.276 x 790.866 pts Page_size
  • 9 Downloads / 177 Views

DOWNLOAD

REPORT


Malaria Journal Open Access

RESEARCH

Field performance of ultrasensitive and conventional malaria rapid diagnostic tests in southern Mozambique Beatriz Galatas1,2*  , Alfredo Mayor1,2,3, Himanshu Gupta1,8, Núria Balanza1, Ihn Kyung Jang4, Lidia Nhamussua2, Wilson Simone2, Pau Cisteró1, Arlindo Chidimatembue2, Humberto Munguambe2, Francisco Saúte2, Pedro Aide2,5 and Quique Bassat1,2,3,6,7

Abstract  Background:  An ultrasensitive malaria rapid diagnostic test (RDT) was recently developed for the improved detection of low-density Plasmodium falciparum infections. This study aimed to compare the diagnostic performance of the PfHRP2-based Abbott Malaria Ag P. falciparum ultrasensitive RDT (uRDT) to that of the conventional SD-Bioline Malaria Ag P. falciparum RDT (cRDT) when performed under field conditions. Methods:  Finger-prick blood samples were collected from adults and children in two cross-sectional surveys in May of 2017 in southern Mozambique. Using real-time quantitative PCR (RT-qPCR) as the reference method, the age-specific diagnostic performance indicators of the cRDT and uRDT were compared. The presence of histidine-rich protein 2 (HRP2) and Plasmodium lactate dehydrogenase (pLDH) antigens was evaluated in a subset from dried blood spots by a quantitative antigen assay. pfhrp2 and pfhrp3 gene deletions were assessed in samples positive by RT-qPCR and negative by both RDTs. Results:  Among the 4,396 participants with complete test results, the sensitivity of uRDTs (68.2; 95% CI 60.8 to 74.9) was marginally better than that of cRDTs (61.5; 95% CI 53.9 to 68.6) (p-value = 0.004), while the specificities were similar (uRDT: 99.0 [95% CI 98.6 to 99.2], cRDT: 99.2 [95% CI 98.9 to 99.4], p-value = 0.02). While the performance of both RDTs was lowest in ≥ 15-year-olds, driven by the higher prevalence of low parasite density infections in this group, the sensitivity of uRDTs was significantly higher in this age group (54.9, 95% CI 40.3 to 68.9) compared to the sensitivity of cRDTs (39.2, 95% CI 25.8 to 53.9) (p-value = 0.008). Both RDTs detected P. falciparum infections at similar geometric mean parasite densities (112.9  parasites/μL for uRDTs and 145.5 parasites/μL for cRDTs). The presence of HRP2 antigen was similar among false positive (FP) samples of both tests (80.5% among uRDT-FPs and 84.4% among cRDT-FPs). Only one false negative sample was detected with a partial pfhrp2 deletion. Conclusion:  This study showed that the uRDTs developed by Abbott do not substantially outperform SD-Bioline Pf malaria RDTs in the community and are still not comparable to molecular methods to detect P. falciparum infections in this study setting. Keywords:  Malaria, Diagnostics, Rapid diagnostic test (RDT), Ultrasensitive, Low density parasitaemia, HRP2, Plasmodium falciparum, Mozambique

*Correspondence: [email protected] 1 ISGlobal, Hospital Clínic - Universitat de Barcelona, Barcelona, Spain Full list of author information is available at the end of the article

Background Despite control and elimination efforts w