Management of Fractured Endodontic Instruments A Clinical Guide
This superbly illustrated book provides detailed information on the causes of instrument failure during endodontic treatment, the factors influencing the management of such cases, and the diverse management options that may be employed to resolve the prob
- PDF / 17,126,208 Bytes
- 284 Pages / 439.43 x 683.15 pts Page_size
- 63 Downloads / 173 Views
A Clinical Guide Theodor Lambrianidis Editor
123
Management of Fractured Endodontic Instruments
Theodor Lambrianidis Editor
Management of Fractured Endodontic Instruments A Clinical Guide
Editor Theodor Lambrianidis Department of Endodontics Aristotle University of Thessaloniki, School of Dentistry Thessaloniki, Greece Illustrated by Dr. Mazinis
ISBN 978-3-319-60650-7 ISBN 978-3-319-60651-4 (eBook) DOI 10.1007/978-3-319-60651-4 Library of Congress Control Number: 2017954328 © Springer International Publishing AG 2018 This work is subject to copyright. All rights are reserved by the Publisher, whether the whole or part of the material is concerned, specifically the rights of translation, reprinting, reuse of illustrations, recitation, broadcasting, reproduction on microfilms or in any other physical way, and transmission or information storage and retrieval, electronic adaptation, computer software, or by similar or dissimilar methodology now known or hereafter developed. The use of general descriptive names, registered names, trademarks, service marks, etc. in this publication does not imply, even in the absence of a specific statement, that such names are exempt from the relevant protective laws and regulations and therefore free for general use. The publisher, the authors and the editors are safe to assume that the advice and information in this book are believed to be true and accurate at the date of publication. Neither the publisher nor the authors or the editors give a warranty, express or implied, with respect to the material contained herein or for any errors or omissions that may have been made. The publisher remains neutral with regard to jurisdictional claims in published maps and institutional affiliations. Printed on acid-free paper This Springer imprint is published by Springer Nature The registered company is Springer International Publishing AG The registered company address is: Gewerbestrasse 11, 6330 Cham, Switzerland
To Virginia for her continuous support and understanding
Contents
1 Introduction: Prevalence of Fractured Instruments. . . . . . . . . . . . . . . . 1 Theodor Lambrianidis 2 Factors Affecting Intracanal Instrument Fracture. . . . . . . . . . . . . . . . . 31 Christos Boutsioukis and Theodor Lambrianidis 3 Mechanisms of Instrument Failure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 Spiros Zinelis 4 Therapeutic Options for the Management of Fractured Instruments. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 Theodor Lambrianidis 5 Parameters Influencing the Removal of Fractured Instruments. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 197 Theodor Lambrianidis and Emmanuel Mazinis 6 Comparative Evaluation of Techniques and Devices for the Removal of Fractured Instruments. . . . . . . . . . . . . . . . . . . . . . . 207 Michael Hülsmann and Theodor Lambrianidis 7 Complications During Attempts of Retrieval or Bypassing of Fractured Instruments . . . . . . . . . . . . . . . . . . . . . . .
Data Loading...