RESEARCH ARTICLE

Open Access

Meta-analysis of contrast-enhanced ultrasound and contrast-enhanced harmonic endoscopic ultrasound for the diagnosis of gallbladder malignancy Xue Liang and Xiang Jing*

Abstract Background: The diagnosis between benign and malignant gallbladder lesions is sometimes difficult. The objective of this study is to assess whether contrast-enhanced ultrasound (CEUS) and contrast-enhanced harmonic endoscopic ultrasound (CH-EUS) can be an accurate method for detecting gallbladder malignancy and to determine which imaging signs can be indicative of malignancy. Methods: A study search of PubMed, Elsevier, and Sciencedirect was performed in May 2019. The pooled sensitivity, specificity, diagnostic odds ratio (DOR), and summary receiver operating characteristic (SROC) curve were used to examine the accuracy of CEUS and CH-EUS. Results: Twenty-one studies were included in the meta-analysis. The pooled sensitivities of CEUS and CH-EUS were 0.81 (0.75–0.86) and 0.92 (0.86–0.95); the specificities were 0.94 (0.90–0.96) and 0.89 (0.69–0. 97); the DORs were 64 (32–127) and 89 (22–354); and the area under the SROC curves were 0.90 (0.87–0.92) and 0.92 (0.90–0.94). On CEUS, the diagnostic criterion for gallbladder malignancy according to four features were analyzed. Sensitivity and specificity were 0.75 (0.65–0.83) and 0.98 (0.85–1.00) for integrity of gallbladder wall; 0.69 (0.55–0.81) and 0.89 (0.77– 0.95) for heterogeneous enhancement; 0.81 (0.71–0.88) and 0.88 (0.76–0.94) for irregular vessels; and 0.81 (0.66–0.91) and 0.75 (0.59–0.86) for washout time within 28 s. On CH-EUS, heterogeneous enhancement could be indicative of malignant lesions with a sensitivity of 0.94 (0.85–0.97); and the specificity was 0.92 (0.71–0.98). Conclusions: CEUS and CH-EUS are promising and reliable imaging modalities with a high sensitivity and specificity for the diagnosis of gallbladder malignancy. CH-EUS might be more sensitive than CEUS with a higher sensitivity. In addition, irregular tralesional vessels and washout time within 28 s on CEUS and heterogeneous enhancement on CH-EUS are indicative of malignancy. However, larger scale and well-designed studies are warranted to verify our results. Keywords: Gallbladder, Contrast-enhanced ultrasound, Endoscopic ultrasonography, Malignant lesions, Diagnosis, Meta-analysis

* Correspondence: [email protected] Department of Ultrasound, Tianjin Third Central Hospital, Tianjin Institute of Hepatobiliary Disease, Tianjin Key Laboratory of Artificial Cell, Artificial Cell Engineering Technology Research Center of Public Health Ministry, No. 83, Jintang Road, Hedong District, Tianjin 300170, China © The Author(s). 2020 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes w