Use of Sustainable Antimicrobial Aggregates for the In-Situ Inhibition of Biogenic Corrosion on Concrete Sewer Pipes

  • PDF / 1,090,264 Bytes
  • 11 Pages / 432 x 648 pts Page_size
  • 6 Downloads / 148 Views

DOWNLOAD

REPORT


MRS Advances © 2020 Materials Research Society DOI: 10.1557/adv.2020.13

Use of Sustainable Antimicrobial Aggregates for the In-Situ Inhibition of Biogenic Corrosion on Concrete Sewer Pipes Ismael Justo-Reinoso1 and Mark T. Hernandez1 1 Department of Civil, Environmental, and Architectural Engineering, University of Colorado Boulder, ECOT 441 UCB 428, Boulder, CO 80309-0428, U.S.A.

*Corresponding author: [email protected]

ABSTRACT

A new generation of cementitious materials is being engineered to selectively inhibit the growth of Acidithiobacillus, which are a key genera of acid-generating bacteria responsible for microbially induced concrete corrosion (MICC). In this context, the substitution of metalladen granular activated carbon (GAC) particles and/or steel slag for a fraction of the fine aggregates traditionally used in concrete mixture has proven useful. While the antimicrobial properties of specific heavy metals (i.e. copper and cobalt) have been leveraged to inhibit acid-generating bacteria growth on sewer pipes, few studies have researched how biocidal aggregates may affect the microstructural and mechanical properties of cementitious materials. We report here on the effects that these biocidal aggregates substitutions can have on compressive strength, flowability, and setting times of cement-based formulations. Results showed that increases in compressive strength, regardless of the presence or absence of biocidal metals, resulted from the GAC incorporation where sand replacement was 3% by mass or lower, while flowability decreased when percentages higher than 3% of GAC was incorporated in a cement mix. When substituting fine aggregate with steel slag particles in mass ratios between 5% and 40%, compressive strength was not affected, regardless of the presence or absence of copper. Setting times were not affected by the inclusion of GAC or steel slag particles except when substituting GAC particles at 10% of the fine aggregate mass; under this condition both initial and final setting times were decreased. Results suggest that in order to have enhanced inhibition potential against acidophilic microorganisms and equal or improved mechanical properties, a combination of 1% metal-laden GAC and 40% copperladen steel slag is an optimum fine aggregate substitution scenario.

Downloaded from https://www.cambridge.org/core. Karolinska Institutet University Library, on 14 Jan 2020 at 09:55:30, subject to the Cambridge Core terms of use, available at https://www.cambridge.org/core/terms. https://doi.org/10.1557/adv.2020.13

INTRODUCTION: Concrete possesses excellent characteristics for water transport applications on large scales. While concrete is recognized for its durability, municipalities and wastewater utilities now realize the extent to which concrete sewer infrastructure is becoming compromised by biogenic corrosion, also known as microbially induced concrete corrosion (MICC). This is a worldwide problem, which in many cases reduces the effective service life of sewers by decades. Modern materia