Microbiological analysis of bacterial and fungal bioaerosols from burn hospital of Yazd (Iran) in 2019

  • PDF / 406,555 Bytes
  • 10 Pages / 595.276 x 790.866 pts Page_size
  • 47 Downloads / 188 Views

DOWNLOAD

REPORT


RESEARCH ARTICLE

Microbiological analysis of bacterial and fungal bioaerosols from burn hospital of Yazd (Iran) in 2019 Akram Montazeri 1 & Hengamah Zandi 2 & Fahimeh Teymouri 1 & Zahra Soltanianzadeh 1 & Sara Jambarsang 3 & Mehdi Mokhtari 1 Received: 25 February 2020 / Accepted: 3 September 2020 # Springer Nature Switzerland AG 2020

Abstract Introduction Bioaerosols play an important role in incidence of infections in indoor and outdoor air of hospitals. Microorganisms play a critical role in the health of human beings and they are found everywhere in the environment, including different wards of a hospital. So, quantitative and qualitative analysis of microorganisms is highly important in hospital air. The aim of this study was to evaluate the diversity and density of bacteria and fungi in the air of Shohadaye Mehrab Hospital in Yazd City, Iran. Materials and methods Sampling was performed using a single-stage pump (Quick Take30) at a flow rate of 28.3 l per minute for five minutes. As a result, 288 indoor and outdoor hospital air samples were collected. Numbers and types of bacterial and fungal colonies were identified using colony morphology, gram staining, and standard microbial tests. Chi-square test, PCA and linear mixed model were run by SPSS version 24.0 for data analysis. Results The highest bacterial contaminations were found in the burns ward (294 CFU/m3), operating theater (147 CFU/m3), and emergency department (124 CFU/m3), respectively. Fungal contamination was higher in the derm ward (110 CFU/m3) than other sampling sites. The dominant genus of gram-positive bacteria was Staphylococcus epidermidis (n = 60, 62.5%) and the dominant genus of gram-negative bacteria was Citrobacter freundi (n = 11, 11.5%). The most fungal gens isolated from the hospital air samples were Penicillium (n = 73, 76%), Alternaria (n = 51, 53.1%), Aspergillus niger (n = 40, 41.7%), and Aspergillus flavus (n = 34, 35.4%), respectively. Conclusion Considering that the burn wounds represent a susceptible site for opportunistic microorganisms, even low concentration of fungi/bacteria in air can be considered as a risk factor that facilitates transmission of the infectious agents in the hospital. Therefore, control measures should be taken to reduce the infection hazard in health staff and patients. These measures include ensuring effective ventilation, cleaning and decontaminating surfaces and equipment, restricting the personnel and patient companions’ movement across the wards. Keywords Hospital . Bioaerosol . Bacteria . Fungi . Airborne

Introduction

* Mehdi Mokhtari [email protected] 1

Environmental Science and Technology Research Center, Department of Environmental Health Engineering, Shahid Sadoughi University of Medical Sciences, Yazd, Iran

2

Research Center for Food Hygiene and Safety, Shahid Sadoughi University of Medical Sciences, Yazd, Iran

3

Research Center of Prevention and Epidemiology of Non-Communicable Disease, Department of Biostatistics and Epidemiology, School of Public Health, Shahid Sadoughi Universit