Correction to: Protein-bound calcium phosphate in uremic rat serum: a quantitative study
- PDF / 428,075 Bytes
- 2 Pages / 595.276 x 790.866 pts Page_size
- 93 Downloads / 187 Views
CORRECTION
Correction to: Protein‑bound calcium phosphate in uremic rat serum: a quantitative study Hong‑Xing Fan1,2 · Bao‑Di Gou3 · Yu‑Xi Gao2 · Gang Wu1 · Shu‑Hu Liu4 · Fan Li4 · Tian‑Lan Zhang3
© Society for Biological Inorganic Chemistry (SBIC) 2020
Correction to: JBIC Journal of Biological Inorganic Chemistry https://doi.org/10.1007/s00775-020-01807-x
In the original article, few equations and units were published incorrectly. The correct equations and units are given below: Page 5: In the first line of the note under Table 2, “Mean ± standard deviation.” should be “mean ± standard deviation (unit: mmol/L).” Page 7: In Eq. (4), “ k ⋅t⋅1 pr ” should be “ K ⋅t⋅1 pr ”. The j [ ] j [ ] whole Eq. (4) should be present as:
[
1 1 1 1 + [ ] [ ]⋅ ]= Kj ⋅ t ⋅ pr fCa t ⋅ pr prCa
(4)
Page 7: In Eq. (5), “0.63610–30.83” should be “0.636 × 10–3 × 0.83”. The whole Eq. (5) should be present as: [ ] t = (1∕intercept)∕ pr (5) = (1∕103)∕(0.636 × 10−3 × 0.83) = 18.4 ≈ 18 Page 8: In line 13 from bottom, “1.76” should be “1.76 mmol/L”. Page 8: In line 12 from bottom, “0.636 × 10–3” should be “0.636 × 10–3 mol/L”. Page 8: In Eq. (9b), “ a2H+ +K ” should be “ a2H+ +K ”. [ ] a2 [ ] a2 The whole Eq. (9b) should be present as: k (uPi−cPi)
] Ka2 (uPi − cPi) [ = [ +] HPO2− 4 H + Ka2 =
The original article can be found online at https://doi.org/10.1007/ s00775-020-01807-x. * Gang Wu [email protected] * Tian‑Lan Zhang [email protected] 1
Department of Preclinical and Forensic Medicine, Baotou Medical College, Inner Mongolia University of Science & Technology, Baotou 014010, People’s Republic of China
2
CAS Key Laboratory for Biomedical Effects of Nanomaterials and Nanosafety, Institute of High Energy Physics, Chinese Academy of Sciences, 19B Yuquan Road, Beijing 100049, People’s Republic of China
3
Department of Chemical Biology, Peking University School of Pharmaceutical Sciences, 38 Xueyuan Road, Beijing 100191, People’s Republic of China
4
Beijing Synchrotron Radiation Facility, Institute of High Energy Physics, Chinese Academy of Sciences, 19B Yuquan Road, Beijing 100049, People’s Republic of China
K (uPi−cPi)
(6.17 × 10−8 )(uPi − cPi) = 0.608(uPi − cPi) (3.98 + 6.17) ⋅ 10−8 (9b)
Page 9: In the end of the paragraph above Eq. (12), “0.15 mmol/L:” should be “0.15 mmol/L.” A full stop. Page 9: In Eq. (14), “1.7310–3” should be “1.73 × 10–3”. The whole Eq. (14) should be present as: [ ] HPO2− ≡ −Intercept∕Km = 0.361∕209 = 1.73 × 10−3 mol∕L 4 0
(14)
Page 9: In Eq. (15), the two semicolons (;) should be deleted. The whole Eq. (15) should be present as: [ ] [ ] ([ ] ) HPO2− − HPO2− > 0 prPi > 0 (15) 4 4 0 Page 10: In Eq. (17a), “ [Ca]⋅ HPO2−1 − HPO2− ” should be ([ 4 ] [ 4 ]) “ [Ca]⋅ HPO2−1 − HPO2− ”. There is a subscript “0”. The whole ([ 4 ] [ 4 ]0 ) Eq. (17a) should be present as:
13
Vol.:(0123456789)
[ ] [ ] prCa prPi K = Kj Km = ([ ] [ ]) ⋅ ([ ] [ ]) t ⋅ pr − prCa prCa − prPi 1 ⋅ ([ ] [ ]) 2− [Ca] ⋅ HPO4 − HPO2− 4 0 (17a)
13
JBIC Journal of Biological Inorganic Chemistry Publ
Data Loading...